Welcome To REPS- "Your Complete Cryogenics Company"

Departments:

CO2 System Sales
Equipment Specifications
CO2 Engineering Data
Absolute Temperature Data
Plumbing Requirements
Conversion Data For Different Types Of Gases



Electric Vaporizer Specifications

Standard Features:

  • Replaceable Heating Elements
  • Weather Proof Cabinets
  • Complete Separation Of Electrical And Plumbing Systems
  • Accurate Temperature Control
  • Silicone Rubber Sealed Heater Terminals
  • Circuit Breaker With Door Interlock
  • High Temp
  • Options:

  • Safety Lo-Temp Shut Off Valve Electric Or "Magic Pipe"
  • Special Fittings In And Out
  • Temperature Indicating Controller
  • Automatic Bypass
  • Special Temperature Controls From -350F To +600F
  • Special Non-Standard Voltages And Frequencies



  • N.P.T. Capacity (15 to 60 KW Shown)

    KW IN* OUT* VOLTS AMPS BC LB./HR. Co2 SCFH N2, O2, AR WT LBS
    15 1/2 1/2 220/440 40/20 6 375 3750 100
    30 3/4 3/4 220/440 80/40 8 1/8 750 7,500 150
    45 3/4 3/4 220/440 120/60 10 1/4 1,125 11,250 180
    60 1 1 220/440 160/80 13 1,500 15,000 210
    75 1 1 220/440 200/100 15 1/4 1,800 18,750 240
    90 1 1 440 120 17 1/2 2,100 22,500 275
    105 1 1 440 140 19 3/4 2,500 26,500 310
    120 1 1 440 160 22 2,900 30,000 345
    135 1 1 440 180 24 1/8 3,200 33,750 375
    150 1 1 1/2 440 200 26 3/8 3,600 37,500 405
    165 1 1 1/2 440 220 28 1/2 4,000 41,250 440
    180 1 1 1/2 440 240 30 3/4 4,300 45,000 575
    195 1 1 1/2 440 260 33 4,700 48,750 605




    How To Contact REPS:

    Send E-Mail To REPS

    Rick Landucci
    23792 Yosemite Blvd.
    Waterford, CA 95386

    Phone: 209-595-7432
    Fax: 209-874-4207